CUSTOMER TIPS
CLI Diagnostics & SSD Wear (Ssaducli)
This article describes how to use the HPE Smart Storage Administrator Diagnostics Utility CLI
Description
This article describes how to use the HPE Smart Storage Administrator Diagnostics Utility CLI (ssaducli), which collects all possible information about storage devices in the system, detects problems, and provides a detailed configuration report. The utility generates two types of reports:
Array diagnostic report
This report contains information (e.g. model, serial number, firmware revision, etc.) about all devices, such as array controllers, storage enclosures, drive cages, as well as logical, physical, and tape drives. For supported solid state drives, this report also contains SmartSSD Wear Gauge information.
SmartSSD Wear Gauge report
This report contains information about the current usage level and remaining expected lifetime of solid state drives attached to the system.
Installation
Download link and Release Notes for HPE Smart Storage Administrator Diagnostic Utility (HPE SSADU) CLI for Linux 64-bit Version:3.47.6.0 (9 Sep 2019):
https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c8ad8ffbe6cb4ea7a86e13e482
Installation:
warning: ./ssaducli-3.47-6.0.x86_64.rpm: Header V3 RSA/SHA256 Signature, key ID 26c2b797: NOKEY
Preparing... ################################# [100%]
Updating / installing...
1:ssaducli-3.47-6.0 ################################# [100%]
Usage
ADU Report Generation
Generate a complete report and save to zipfile reportFileName:
-v : Verbose output.
-slot : Report for the controller at this slot.
Generate a standard text report and save to file textReportFileName:
-f textReportFileName : Save output to textReportFileName.
-v : Verbose output.
Smart SSD Wear Gauge Report Generation
Generate a complete report and save to zipfile reportFileName:
-v : Verbose output.
-slot : Report for the controller at this slot.
-f textReportFileName : Save output to textReportFileName.
-v : Verbose output.
EXAMPLES
Check All Device Model Numbers And Firmware Revisions
# egrep 'Physical Drive Status|Drive Model|Drive Firmware Revision' HCIJSCALSTOR01_ssaducli_adu.txt
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (1.9 TB SATA 512e SSD) 1I:1:10 :
Physical Drive Status
Drive Model ATA MK001920GWJPQ
Drive Firmware Revision 4IYVHPG3
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (1.9 TB SATA 512e SSD) 1I:1:11 :
Physical Drive Status
Drive Model ATA MK001920GWJPQ
Drive Firmware Revision 4IYVHPG3
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (10 TB SATA 512e HDD) 1I:1:13 :
Physical Drive Status
Drive Model ATA MB010000GWAYN
Drive Firmware Revision HPG3
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (10 TB SATA 512e HDD) 1I:1:14 :
Physical Drive Status
Drive Model ATA MB010000GWAYN
Drive Firmware Revision HPG3
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (10 TB SATA 512e HDD) 1I:1:15 :
Physical Drive Status
Drive Model ATA MB010000GWAYN
Drive Firmware Revision HPG3
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (10 TB SATA 512e HDD) 1I:1:16 :
Physical Drive Status
Drive Model ATA MB010000GWAYN
Drive Firmware Revision HPG3
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (10 TB SATA 512e HDD) 1I:1:17 :
Physical Drive Status
Drive Model ATA MB010000GWAYN
Drive Firmware Revision HPG3
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (10 TB SATA 512e HDD) 1I:1:18 :
Physical Drive Status
Drive Model ATA MB010000GWAYN
Drive Firmware Revision HPG3
SSD Wear Report
Note: The output of the utility may vary because of different versions of the utility and/or controller and device firmware.
Smart Storage Diagnostics 3.47.6.0 2019-07-15
ADU Version 3.47.6.0 2019-07-15
Diagnostic Module Version 3.47.6.0 2019-07-15
Time Generated Wednesday November 27, 2019 1:53:02AM
Device Summary:
Smart Array P440 in slot 1
Smart Array P440 in slot 2
Smart HBA H244br (RAID Mode) in Embedded Slot
Report for Smart Array P440 in slot 1
-------------------------------------
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (1.9 TB SATA 512e SSD) 1I:1:10 : SSD Wear Gauge
Status OK
Supported TRUE
Log Full FALSE
Utilization 1.860000
Power On Hours 10008
Has Smart Trip SSD Wearout FALSE
Remaining Days Until Wearout 22002
Has 56 Day Warning FALSE
Has Utilization Warning NONE
Smart Array P440 in slot 1 : Internal Drive Cage at Port 1I : Box 1 : Physical Drive (1.9 TB SATA 512e SSD) 1I:1:11 : SSD Wear Gauge
Status OK
Supported TRUE
Log Full FALSE
Utilization 1.880000
Power On Hours 10009
Has Smart Trip SSD Wearout FALSE
Remaining Days Until Wearout 21766
Has 56 Day Warning FALSE
Has Utilization Warning NONE
If this does not solve your issues please get in touch with support